Solid/PowderSampleHolder
(Cat. No. 206-67779)
Used for the measurement of solid or
powder samples in the reflection
mode.
The angle of the holder is adjusted so
that the directly reflected excitation
beam may not enter the emission
monochromator.
Standard accessories
Powder sample tray: 1 pc.
Quartz plate: 1 pc.
Spacer 1: 2 pcs.
Spacer 2: 1 pc.
Powder leveling rod: 1 pc.
Spacer 2: 1 pc.
Powder leveling rod: 1 pc.
Options
Filter set
(Cat. No. 206-80154)
Minimizes the influence of scattered light.
8 mm dia. Test Tube Holder
(Cat. No. 206-69956)
Holds a test tube, 8 mm OD.
Used for measurements in a wavelength
range longer than 400 nm, because
the ordinary glass used for test tubes
are opaque in the UV region. Test
tubes made of Pyrex glass are used
in a wavelength range longer than
350 nm.
Accepts a test tube, 8 mm OD and 50
to 85 mm long.
Options: 8 mm dia. test tube (Pyrex glass)
(Cat. No. 208-97200)
12mm dia.Test TubeHolder
(Cat. No. 206-67777)
Holds a test tube, 12 mm OD., in
place of an ordinary square cell.
Used for measurements in a
wavelength range longer than 400
nm, because the ordinary glass used
for test tubes is opaque in the UV
region. Test tubes made of Pyrex
glass are used in a wavelength range
longer than 350 nm.
Accepts a test tube, 12 mm OD and 45
to 85 mm long.
Options: 12 mm dia. test tube (Pyrex glass)
(Cat. No. 200-93068)
Flow-Thru Cell Unit
for HPLC
(Cat. No. 206-69220)
Converts an RF-1501 into a spectroflu-
orometric detector for HPLC.
An analog output interface is required
when the data is to be processed with
a data processor, e.g. Chromatopac.
Standard accessories
Flow-thru cell: Square cell made of
fused silica
Cell volume: 12
μ
L
Pressure resistancy of cell:
2.9
×
10
6
Pa (30 kgf/cm
2
)
Related items
Analog Output Interface
(Cat. No. 206-69240)
Sensitivity Enhancing
Cell Holder
(Cat. No. 206-67783)
Enhances measuring sensitivity two or
three times, by reflecting back the
light that has transmitted through the
cell to make it pass the cell again, to
raise the excitation efficiency.
Also enhances the light capture yield
by reflecting the emission beam,
emitted to the other side of the
emission monochromator, back to that
monochromator.
Constant-Temperature
Cell Holder with Stirrer
(Cat. No. 206-80496)
Keeps the sample cell at the desired,
constant temperature, by circulating
temperature controlled water.
Effective for temperature-sensitive
applications, such as measurement of
intracellular calcium ions.
Equipped with a magnetic stirrer to stir
the sample during measurement.
(The stirrer controller is required,
which is described below.)
Specifications
Method: Forced circulation of temperature
controlled water
Applicable sample cell: 10 mm square
cell polished on four sides
Circulating water temperature:5
to
60
Stirrer speed: 100 to 1,000 r.p.m.
Related items
CC301 Stirrer Controller
(Cat. No. 044-31006-
**
)
NTT-1200P Constant-Temperature Water Circulator
(Cat. No. 208-97242)
9