Analog Output Interface
(Cat. No. 206-69240)
・
Outputs voltage signals proportional to
the fluorescence intensity.
・
Specifications
Resolution: 18 bits
Output: 1 V/FS, 100 mV/FS
ASC-5Auto Sample Changer
(Cat. No. 204-09100)
・
Builds an automatic multisample
spectrophotometry system in
combination with a sipper unit.
・
The aspirating nozzle is programmable
to move in the X, Y, and Z (vertical)
directions.
・
Up to 8 sets of operational parameters,
including the size of racks and the
number of test tubes, may be
memorized in the battery back-up
protected files.
・
An RS-232C interface
(Cat. No. 204-09079)
and a GP-IB interface
(Cat. No. 204-09155)
are optionally available to allow an
external computer to control the ASC-
5 directly.
・
Up to 100 test tubes may be set
together on the rack.
R928-08 Photomultiplier
Tube
(Cat. No. 200-75021)
・
Replacing the standard photomultiplier
tube of the RF-1501 with this tube
extends the measuring wavelength
range to 900 nm.
Sipper Unit 1500
(Cat. No. 206-69720)
・
Aspirates solution samples one after
another, using a peristaltic pump
driven by a stepping motor, to be
measured successively.
・
Specifications
Flow-thru cell: Square flow-thru cell
made of fused silica.
Cell capacity: 120
μ
L
Aspiration speed: FAST, MEDIUM,
and SLOW.
Minimum sample volume: 2 mL
(Less than 1% carry-over)
Linked operation with the ASC-5
Auto Sampler possible.
・
Standard accessories
Drain tank
Tygon tube, 2.5 meters long, for pump
connection
ASC-5 connecting cable
・
Options and Supplies
Solenoid Valve Unit with wetted
parts made of Teflon
(Cat. No. 206-69824)
SWA-2 Sample Waste Unit
(Cat. No. 204-29230)
Note:The tubing of the standard
peristaltic pump is not resistant enough
against strong acids, strong alkalis, and
ester solutions; use of the above
mentioned Solenoid Valve Unit and
SWA-2 is recommended.
Tygon tube for pump
(Cat. No. 200-84523-04)
NTT-2200P Constant-
Temperature Water
Circulator
(Cat. No. 208-97263)
・
Circulates temperature controlled
water to a constant-temperature cell
holder.
・
Temperature range:
Ambient +5
℃
to +80
℃
・
Temperature control precision:
±
0.05
℃
∼
・
Max. pumping rate:
27/31 L/min, 9.5/13 m (50/60 Hz)
・
External circulation nozzle:
10.5 mm OD (both outlet and return)
・
Tank capacity: About 10 L
(9 L during use)
・
Safety feature:
Detection of over-temperature of
Upper or Lower limits, Detection of
heater wire malfunction, Protection of
heating too few circulating water,
Detection of sensor malfunction,
Independent over teat protection,
Over current circuit protector
・
Standard accessories:
Lid with handles, Rubber hose (4m),
Hose clamps (4pc.), Instruction
manual
・
Dimensions:270W
×
560H
×
400D
(mm)
・
Power requirements:
100 VAC, 1250 VA,with 1.7 m power
cord and grounded plug
10